• 10% off Float Level Gauge for General Routine Applications
  • 10% off Float Level Gauge for General Routine Applications
  • 10% off Float Level Gauge for General Routine Applications
  • 10% off Float Level Gauge for General Routine Applications
  • 10% off Float Level Gauge for General Routine Applications
  • 10% off Float Level Gauge for General Routine Applications

10% off Float Level Gauge for General Routine Applications

After-sales Service: Free Technical Guidance
Principle: Magnetic Sensors
Range: 0-15m
Measurement Accuracy: ±5mm
Accuracy: 0.1%
Kind: Float
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
UHC
Structure
All in One
Warranty
1 Year
Certification
CE
Material
SS304
Process Temperature
-40~120℃
Transport Package
Wooden Packing
Specification
50.00cm * 50.00cm * 120.00cm
Trademark
Vacorda
Origin
China
HS Code
9026100000
Production Capacity
400 Pieces Per Week

Product Description

10% off Float Level Gauge for General Routine Applications
Working Principle:

Magnetic level sensor consists of reed, precise resistance and amplification transformation circuit and adopt imported advanced sensor components and signal transmitters. When the magnetic line of the magnetic float ball reaches a certain place of the level sensor, the reed closes, and the float ball changes with the height of level interface. The amplification transformation circuit converts the change of the interface height into linear 4~20mADC signal to realize the measurement and transmission of the level location signal.
Features:
1. Simple structure, good stability and reliability.
2. Independent of medium's physical and chemical states such as conductivity, dielectric constants, foam etc.
3. Applicable for all kinds of medium environment such as corrosive, toxic and explosive one.
4. Interface measurement or level measurement of 2 kinds of medium with different density.
5. Explosive-proof design
6. Two-wire 4~20mADC signal output, 0.56" LED digital display.

Application:  
UHC series magnetic flap liquid level gauge is widely used in petroleum, chemical industry, oil field, pharmaceuticals industry, food, wine industry etc.


The Circuit principle diagram:



Accuracy class:

Accuracy class:       Resolution x 100    x %
                   Measuring range(mm)
Note:as the same resolution, the measuring range more wide,the accuracy will be more high.
For example: resolution:10mm, measuring range:1000mm, accuracy:1%
            resolution:10mm, measuring range:2000mm, accuracy:2%





Main Technical parameters:
 
Measuring Range 200~6000mm(>6M customize)
Resolution Factor 10mm,5mm,20mm
Signal Output 4~20mA(two -line)
200Ω/m(1/2'', 3/8'')
Loading Resistance 500Ω
Transmitting >1000m
Working Power Supply 16~30VDC
Density 0.5g/cm3
Pressure PN2.5~PN160(×0.1MPa)(Max pressure PN320)
Operating Temperature -40 ~ 80 °C, 120 °C,150 °C
Float Ball Diameter Ф30~Ф120(depending on pressure and density)
Flange Installation DN40~DN150/RF/PL(HG/T20592~2009) customized
2'' thread (downward install)
1/2'' thread (upward install, resistance signal output)
3/8'' thread (upward install, resistance signal output)
Installation Angle ±25°
Electrical Connection M20×1.5 female thread
Three-lines screening cable
IP Grade IP65
Explosion-Proof Grade Exia II CT6Ga, EXd II CT6Gb








How to order: UHC- 
 
1 Installation type
  DN/sealing face/flange 02(down) 03(up) 04(up) K
Standard:HG/T 20592,20615-09 G1/2"thread G2"thread G3/8"thread DIN bayonet-type

 
Z A B C D E F G H
 2.5 6 10 16 25 40 63 100 160
Flange standard: when PN40, flangeDN125
3 Tube material
  P1-304 P2-316L P3-321 P4-1Cr18Ni9Ti P5-0Cr18Ni9Ti P6-00Cr17Ni14Mo2
  PP  T-Titanium F-304+PTFE QF-Poly perfluorovinyl  
4 Float ball material
  P1-304 P2-316L P3-321 P4-1Cr18Ni9Ti   P5-0Cr18Ni9Ti   P6-00Cr17Ni14Mo2
PP T-Titanium F-304+PTFE QF-Poly perfluorovinyl  
5 pipe Dia
  14 16 20 8 T
14mm(standard) 16mm 20mm 8mm Special need
6 Medium density
     -liquid level measurement-indicate the density (g/cm3 or kg/m3)
     /    -interface measurement-indicate the density of 2 kinds of medium(g/cm3 or kg/m3)
7 Operating temperature
  L:80ºC H:120ºC J:150ºC(consulting)
8 Installation depth L/ measuring range M  
     /   --installation depth/measuring rang M(mm, M=L-L1-X, X=1/2 length of float ball+30)
Note:Maximum measuring range<=installation depth L-length of float ball-30
9 Resolution
  B10:10mm(normal) B5:5mm B20:20mm T: special requirement
10 Signal output
  A B C D
  4~20mA 4~20mA with HART 0~20mA 0~10mA
11 Indicator
  No mark:N/A M1:Needle meter M2:LED M3:LCD(HART)  
12 Explosion - proof
  No mark:N/A i:Exia II CT6Ga e:Exd II CT6Gb

Float ball
material
Float Di
(mm)
Do
(mm)
H
(mm)
Max operating pressure(PN) Operating temperature(ºC) Standard density Critical densityg/cm3
1Cr18Ni9Ti316L V24 9 24 24 10-16 150 1.0 0.8
V28 9 24 28 10-16 150 1.0 0.78
V38 9 38 27 10-16 150 1.0 0.55
V45 16 45 50 10-16 150 1.0 0.6
V51 16 51 60 10-16 150 1.0 0.5
V75 16 75 75 25 150 1.0 0.55
V125 22 125 125 25 150 1.0 0.55
V110 16 110 110-180 40-63 150 1.0 0.8
Titanium T95 16-22 95 110-180 40-160 150 1.0 0.5
T110 16-22 110 110-180 40-160 150 1.0 0.5
PTFE F48 22 48 70-100 6-16 150 1.0 0.7

PP
P48 24.5 48 60-120 6-20 ≤90 1.0 0.8
P58 24.5 58 60-120 6-20 ≤90 1.0 0.6
P76 24.5 76 70-120 6-16 ≤90 1.0 0.5
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
71
Year of Establishment
2005-06-29