Customized Conductive Liquid Factory Electromagnetic Flow Meter

Product Details
Customization: Available
After-sales Service: Free Guidance
Warranty: 1 Year
Still deciding? Get samples of US$ 400/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
71
Year of Establishment
2005-06-29
  • Customized Conductive Liquid Factory Electromagnetic Flow Meter
  • Customized Conductive Liquid Factory Electromagnetic Flow Meter
  • Customized Conductive Liquid Factory Electromagnetic Flow Meter
  • Customized Conductive Liquid Factory Electromagnetic Flow Meter
  • Customized Conductive Liquid Factory Electromagnetic Flow Meter
  • Customized Conductive Liquid Factory Electromagnetic Flow Meter
Find Similar Products

Basic Info.

Accuracy
≤±0.1%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil
Size
DN10-DN1200
Sensor
Tube/Flange
Application
Industrial Production
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Liquid
Certification
CE, ISO
Protection Class
IP65, IP67
Transport Package
Wooden Box
Specification
Small
Trademark
Vacorda
Origin
China
HS Code
902610000
Production Capacity
1200pieces/Month

Product Description

Customized Conductive Liquid Factory Electromagnetic Flow meter
Why choose us:
1. 23 years of instrumentation equipment production experience
2. Product support OEM / ODM, export to more than 100 countries
3. The company area 20,000 square meters, and 150+ orders per month
4. Provide email, skype, whatsapp 24-hour one-on-one technical support service online

 
Working Principle
Working principle of electromagnetic flow meter measurement is based on the Faraday law of electromagnetic induction. Measurements of the flow meter tube is lined with insulating material of a non-magnetic alloy spool. Two clicks along the diameter through-wall fixing on the measuring tube. The electrode head is flush with the lining inner surface. Field coil by waves when pulsed excitation by both parties, will be measured perpendicular
to the pipe axis direction produces a magnetic flux density of the magnetic field b. At this point, if you have
some electrical conductivity of fluid flows through the measuring tube, cut magnetic lines of induction electromotive force.

Technical parameters
Nominal diameter DN(mm) 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600,800, 1200  Note: special specifications can be customized
Flow direction positive and negative, net flows
Measuring range ratio 150:1
Repeatability error ±0.1%
Accuracy Pipe type: 0.5, 1.0
Measured medium temperature Common rubber lining: -20~+60 ºC
High temperature rubber lining: -20~+90 ºC
PTFE lining: -30~+100 ºC
High temperature vinyl lining: -30~+180 ºC 
Rated working pressure Pipe type: DN10~DN65: ≤ 2.5MPa; DN80~DN150: ≤ 1.6MPa;
DN200~DN1200: ≤ 1.0MPa
Special type up to 10.0MPa
Flow measuring range flow measuring range corresponding to flow rate range is 0.3~15m/s
Measured fluid conductivity 5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)
Output 4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA
Load resistance < 600 Ω
Electrode material 316L, titanium(Ti), tantalum(Ta), Hastelloy(H), Platinum(Pt) or other special electrode materials
Protection grade Standard: IP65; Diving type:IP68
Working power supply 85~265VAC 45~63HZ
Straight pipe length Pipe type: ≥ 5DN in the upper reaches, downstream :≥2DN
Connections flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements.
Explosion-proof mark ExdCT6 
environment temperature -25 ºC ~+60 ºC
Relative humidity 5%~95%
Total power consumption <20W
 
About US

Customized Conductive Liquid Factory Electromagnetic Flow Meter
Customized Conductive Liquid Factory Electromagnetic Flow Meter
Customized Conductive Liquid Factory Electromagnetic Flow Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier