Customization: | Available |
---|---|
Type: | Micro - Differential Pressure Transmitter |
Feature: | Intelligent |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Why choose us
1. 23 years of instrumentation equipment production experience
2. Product support OEM / ODM, export to more than 100 countries
3. The company area 20,000 square meters, and 150+ orders per month
4. Provide email, skype, whatsapp 24-hour one-on-one technical support service online
Application:
liquid, gas, steam.
Product Parameters
Measuring range |
0~32MPa |
Accuracy |
1. Digital Signal: ± 0.05 ; |
Load Resistance |
0-600Ω (24VDC power) |
Stability |
± 0.2% FS / Year ( t = 28 °C, the maximum static pressure 6.9 MPa, range 1:1 condition) |
Zero and range |
External continuously adjustable |
Positive transfer |
500% |
Negative transfer |
600% |
Static pressure effect |
1. Zero Error (can eliminate the static pressure) |
Environmental temperature influence/ 28 °C |
1. Turndown ratio 1:1-10:1 ≤ ± 0.2% |
Power influence |
<0.005% / V |
Vibration Impact |
arbitrary axis on the 15-2000Hz test ±<0.1% FS |
Location of installation |
a maximum of 250Pa zero may be amended, no range effect |
Dielectric strength and reverse protection |
terminal and the shell, 50Hz, 100Vpp lasted for one minute |
without arcing |
24VDC reverse without damage |
Power supply |
12-45VDC |
Environment temperature |
-40 - +50 °C |
Relative humidity |
0-100% |
Citation pressure connection |
1. Citation pressure hole: 1/4NPT internal taper pipe thread |
Diaphragm |
316L, HC-276, Monel, Tantalum |
drain / vent valve |
316L, HC-276 or Monel optional |
Sensor 0 type seal ring |
NBR, PTFE, metal seals |
Sensor Fill Fluid |
silicone oil, fluorine oil |
Outer case and coating |
Low copper aluminum alloy, anodizing, painting polyurethane |
Explosion-proof grade |
1. Intrinsically safe (i) Exia ii CT6 Ga |