Customization: | Available |
---|---|
After-sales Service: | Free Technical Guidance |
Principle: | Magnetic Sensors |
Still deciding? Get samples of US$ 135/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
5%off Customized Magnetic Tank Oil Water Fuel Liquid Floating Boiler Level Gauges
Product Description
Patent Design Magnetic Float Level Gauge Boiler Drum Type used in high temperature, high pressure and low density conditions such as boiler steam drums and high heaters;The main material can be selected from 304, 316L, 321, etc.Patented magnetic float design, high temperature and high pressure resistance;The anti vaporization device effectively mitigates the influence of false liquid level;Can output 4-20ma+HART signal output and switch signal outputWorking Principle
Product Parameters
Center-center distance: | 150~6000mm |
Medium density: | More than 0.45g/cm3 |
Nominal pressure: | PN6~PN63(x 0.1MPa) |
Material: | SS304, 316L, PP, PTFE, or customized |
Operating temperature: | <80 °C |
Process connection: | Flange or customized |
Indicator types: | |
A: Al &ABS flap cylinder | B: Al flap plate |
C: PVC ABS flap cylinder | D: PP&ABS flap cylinder |
E: AL &LED | F: PP&LED |
Structure of top chamber: | 1.Welding cover 2.welding cover with M14*1.5 plug screw 3.flange 4.flange with M14*1.5 plug screw 5.welding cover with DN20 flange 6.flange with DN20 flange 7.welding cover with air valve 8.flange with air valve |
Structure of bottom chamber: | 1.flange cover 2.flange with drain plug screw 3.flange with DN20 welding tube 4.with DN20 flange 5.with needle/ball valve |
Protection class: | IP65 |
Notes on choosing the top-mounted magnetic levitation level gauge
1. Anti-corrosion nominal pressure &LE; 1.0MPa.
2. The level gauge has a certain blind zone. When reading the height of the level, the blind zone value compensation should be added (when the level gauge leaves the factory, the scale zero has been moved to the actual value).
3. The range of the level gauge should not exceed 5 meters, otherwise the stability, reliability and color fastness of the level gauge will be affected.
4. Install the connecting flange, which is usually manufactured by the protruding surface dimension reference (HG 21592-97).
Installation, use and maintenance of the top-mounted magnetic levitation level gauge
1. The protection pipe of the level gauge and the main pipe must be kept vertical.
2. The connecting rod cannot be bent and must be inserted straight
3. After installation, use the magnet to guide the display to flip the column once, and the white is above zero and the red is below zero.
Precision instruments such as the maglev level gauge installed on the top must be selected according to the ratio of the three kinds of goods, otherwise it may cause irreparable errors. If you want to know more, welcome to visit our website for a long time.
Company InformationSichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-working and truth-seeking characters. Solid foundation has been established.
In 2017, we moved into our new factory whhich occupies the area about 20000 square meter, the workshop of 6900 square meter, R&D department of 1180 square meter, integrated office building of 1260 square meter, and we have established the high accuracy flow calibration lines.CertificatePackage
FAQ
Q: The new magnetic flap liquid level gauge can't show liquid level?
A: 1.check whether there is block in by pass pipe 2.check the the density of medium 3.check whether the float ball is stucked by float ball.
Q: The longest length of magnetic flap liquide level gauge?
A: the length is customized,but in order to be convenient for transport,if the length is over 6m,we recommend
Q: If the float ball is installed at the wrong opposite direction,what's the influence?
A: reading level will be higher than true level,usually higher by length of floatball-70mm
Q: What's installation details of magnetic flap liquid level gauge ?
A: 1.before installation,check specification with label plate. 2.There shouldn't magnetic field within 400m
Q: There is problem in output signal 4--20mA?
A: 1.Check working power supply 2.check wiring 3,check load resistance 4.verify measuring range,zero point
Q: what's specification we need to know before purchasing magnetic flap liquid level gauge?
A: medium density,working temperature,working pressure,material,flange center to center distance,flange standard,whether need 4--20mA output signal;wether need level alarm