5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price

Product Details
Customization: Available
After-sales Service: Free Technical Guidance
Warranty: Free Technical Guidance
Still deciding? Get samples of US$ 288/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
71
Year of Establishment
2005-06-29
  • 5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
  • 5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
  • 5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
  • 5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
  • 5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
  • 5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
HKLD
Accuracy
≤±0.1%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN10-DN800
Sensor
Tube/Flange
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
CE, RoHS, ISO
Meter Accuracy
Piped: 0.5 Class, 1.0 Class
Measuring Range Ratio
150:1
PTFE Lined Pipe
10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150
Rubber Lined Pipe
40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400
Transport Package
Wooden Box
Specification
make to order
Trademark
Vacorda
Origin
China
HS Code
90261000
Production Capacity
100 Piece Per Week

Packaging & Delivery

Package Size
150.00cm * 100.00cm * 120.00cm
Package Gross Weight
100.000kg

Product Description

Product Description

Manufacturer Customized IP68 316L Stainless Water Electromagnetic Flowmeter Electromagnetic Flow Meter Price 

5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
Production Description
Electric medium highly sensitive quality Electromagnetic flow sensor for industry is a fully intelligent electromagnetic flowmeter developed by our company using the most advanced technology at home and abroad. Its electromagnetic converter core adopts high-speed central processing unit. The calculation speed is very fast, the precision is high, and the measurement performance is reliable. The sensor adopts non-uniform magnetic field technology and special magnetic circuit structure, the magnetic field is stable and reliable, and the volume is greatly reduced, the weight is reduced, and the flowmeter is characterized by small flow.
Detailed Photos

5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price

Product Parameters

 

Certifications
 
PTFE Lined Pipe 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400,450, 500, 600
Rubber Lined Pipe 40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200,note: special specifications can be customized
Flow Direction positive and negative, net flows Turndown
Measuring Range Ratio 150:01:00
Accuracy: piped: 0.5 class, 1.0 class
Measured Medium Temperature Common rubber lining: -20~+60 ° c
High temperature rubber lining: -20~+90 ° c
PTFE lining: -30~+100 ° c
High temperature vinyl lining: -30~+180 ° c
Rated Working Pressure pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;
DN200~DN1200: ≤ 1.0MPa
Flow Measuring Range flow measuring range corresponding to flow rate range is 0.3~15m/s
Measured Fluid Conductivity 5μs/cm (Most with water as the composition of the medium,its conductivity in the range 200~800 Mu s/cm, optional
Repetitive Error +/-0.1%
5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price
Company Profile

5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price5%off Manufacturer Customized 316L Stainless Water Electromagnetic Flowmeter Price

Our Advantages

1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.
2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.
3. On-site modification of the measuring range available.
4. LCD display, easy to use and simple to operate.
5. Using SMD devices and SMT technology.
6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.
7. Anti-interference, reliability, measurement range up to 150:1.
8. Ultra low EMI switch, wide range of power supply voltage.
9. RS485, RS232, Hart and Modbus digital communication signal output.
10. Self-checking function.

FAQ

Q: The new magnetic flap liquid level gauge can't show liquid level?
A: 1.check whether there is block in by pass pipe 2.check the the density of medium 3.check whether the float ball is stucked by float ball.

Q: The longest length of magnetic flap liquide level gauge?
A: the length is customized,but in order to be convenient for transport,if the length is over 6m,we recommend

Q: If the float ball is installed at the wrong opposite direction,what's the influence?
A: reading level will be higher than true level,usually higher by length of floatball-70mm

Q: What's installation details of magnetic flap liquid level gauge ?
A: 1.before installation,check specification with label plate. 2.There shouldn't magnetic field within 400m

Q: There is problem in output signal 4--20mA?
A: 1.Check working power supply 2.check wiring 3,check load resistance 4.verify measuring range,zero point

Q: what's specification we need to know before purchasing magnetic flap liquid level gauge?
A: medium density,working temperature,working pressure,material,flange center to center distance,flange standard,whether need 4--20mA output signal;wether need level alarm


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now