V-cone flow meter is a differential pressure type flow measurement device. So far it is more than 100 years since all kinds of flow measurement device that based on pressure differential theory been used. Pressure differential theory is based on energy conversion principle in sealed piping, means that to the steady liquid, flux and flow velocity's square root is direct ratio.
Product features
1.Low installation requirement: Rectifying behavior changes the velocity distribution, eliminating the eddy current and blind space.upstream straight pipe 0-30D, downstream straight pipe 0-1D.
2. Turndown ratio : 10:1 (usually);50:1(maximum)
3. Small pressure loss and signal stability: V-cone differential pressure signal is high-frequency low-amplitude signals.When the same β value, the pressure loss is 1/3~1/5 of orifice plate's and signal fluctuation is 1/10 of orifice plate's.
4.Strong resistance against wear: After the streamline V cone is throttled, the vacuum effect will be generated on the surface of V cone to keep the V cone from being worn easily.
5.Automatic cleaning, no block, no adhesion: the complete purging design of V cone avoids the settlement of residue, coagulation or particle.
6.Long-standing favorable stability: the value of β can remain the same for long and the accurateness in measurement can be ensured for a long period.
7.High precision and good repeatability: accuracy:±0.5% F.S; repeatability:±0.1% F.S
8.Wide range of the value of β: the unique geometrical shape of V cone flow sensor allows wide range of the value of β.
9.Type specification complete, multi-choice of installation:pipeline, flange tapping, wafer and plug-in.
Product Parameters
(1)Long-term stability: | ± 0.1% F.S / Y |
(2)Output: | 4~20mA |
(3)Repeatability: | ± 0.1% |
(4)Minimum flow velocity: | 0.1m |
(5)Turndown ratio: | Normally15:1; max50:1 |
(6)Reynolds number range: | 8 × 103 ~ 5 × 106 |
(7)Operating pressure: | ≤ 16MPa, 42MPa(maximum) |
(8)Operating temperature: | -160 °C ~ 700 °C |
(9)Nominal diameter: | φ15~φ2000 (1/2"~120") |
(10)Environment temperature: | ≤ 80 °C |