HBY301 Hydro-static Liquid Level Gauge
Working Principle:
HBY301 hydrostatic liquid level gauge utilizes the linear variation of liquid height, density and pressure to convert the variation of the level into linear 4~20mADC standard signal.This liquid level gauge adopts imported highly stable sensors and temperature compensation correction technology to achieve such top features as good anti-interference, reliability and good stability.
Features:
- Level of acid, alkali or none-corrosive mediums measurements.
- High anti-interference,stability and reliability
- Lighting-proof design
4.Customization.
Application:
HBY301 hydrostatic level gauge can be widely used to measure the level and pressure of open containers with acid, alkali or non-corrosive mediums in the field of petroleum, iron and steel, metallurgy, oil, light industry, chemical industry, thermal power plants, sewage treatment and other industries.
Product structure:
Installation diagram:
Technical parameters:
Measuring range |
Liquid level:0~50m |
Pressure:0.1~0.6MPa |
Accuracy |
0.5 |
Signal output |
4~20mADC, 0~20mA |
Loading resistance |
0~600Ω |
Transmitting distance |
>1000m |
Working voltage |
24VDC |
Working temperature |
-50~ +80 °C |
Environmental temperature |
-40~ +50 °C |
Relative humidity |
≤85% |
Contacting liquid material |
Stainless steel, PP, PTFE |
Installation flange |
DN32 (Standard flange: HG/T20593,20595-97) RF sealing face |
electrical connection |
M20×1.5 |
Explosion-proof grade |
Exia II CT6Ga Exd II CT6Gb |
How to order: HBY301-1-2-3-4-5-6
1 |
Flange material |
|
P |
L |
F |
PP |
X |
304 |
316L |
PTFE |
PP |
customized |
2 |
Signal output |
|
4: 4~20mA |
0: 0~20mA |
|
3 |
Indicator |
|
N |
M1 |
M2 |
M3 |
4 |
Flange |
|
32 |
50 |
80 |
X |
DN32 |
DN50 |
DN80 |
Customize |
5 |
Explosion - proof code |
|
No mark:N/A |
i: Exia II CR6Ga |
e:Exd II CT6Gb |
6 |
Measuring range(m) |
|
Measuring length(m) |
HBY302 Hydro-static Liquid Level Gauge
Working Principle:
HBY302 hydrostatic liquid level gauge utilizes the linear variation of liquid height, density and pressure to convert the variation of the level into linear 4~20mADC standard signal.This liquid level gauge adopts imported highly stable sensors and temperature compensation correction technology to achieve such top features as good anti-interference, reliability and good stability.
Features:
1.High anti-interference,stability and reliability
2.Lighting-proof design
3.Customization.
Application:
HBY302 hydrostatic level gauge can be widely used to measure the level and pressure of open containers with acid, alkali or non-corrosive mediums in the field of petroleum, iron and steel, metallurgy, oil, light industry, chemical industry, thermal power plants, sewage treatment and other industries.
Product structure:
Technical parameters:
Measuring range |
0~200m |
Accuracy |
0.5 |
Signal output |
4~20mADC, 0~20mA |
Loading resistance |
0~600Ω |
Transmitting distance |
>1000m |
Working voltage |
24VDC |
Working temperature |
-50~ +80 °C |
Environmental temperature |
-40~ +50 °C |
Relative humidity |
≤85% |
Contacting liquid material |
Stainless steel, PP, PTFE |
Installation flange |
1,DN32 (Standard flange: HG/T20592-2009) RF sealing face |
2,No fixed device (or customize) |
electrical connection |
M20×1.5 |
Explosion-proof grade |
Exia II CT6Ga Exd II CT6Gb |
How to order: HBY302- 1-2-3-4-5-6
1 |
Insert head material |
|
P |
L |
F |
PP |
X |
304 |
316L |
PTFE |
PP |
customize |
2 |
Signal output |
|
4: 4~20mA |
0: 0~20mA |
|
3 |
Indicator |
|
N |
M1 |
M2 |
M3 |
4 |
Flange |
|
32 |
50 |
N |
X |
DN32 |
DN50 |
None fixed device |
Customize |
5 |
Explosion - proof code |
|
No mark:N/A |
i: Exia II CR6Ga |
e:Exd II CT6Gb |
6 |
Measuring range(m) |
|
Measuring length(m) |
HBY303 Hydro-static Liquid Level Gauge
Working Principle:
HBY303 hydrostatic liquid level gauge utilizes the linear variation of liquid height, density and pressure to convert the variation of the level into linear 4~20mADC standard signal.This liquid level gauge adopts imported highly stable sensors and temperature compensation correction technology to achieve such top features as good anti-interference, reliability and good stability.
Features:
1.High anti-interference,stability and reliability
2.Lighting-proof design
3.Customization.
Application:
HBY303 hydrostatic level gauge can be widely used to measure the level and pressure of open containers with acid, alkali or non-corrosive mediums in the field of petroleum, iron and steel, metallurgy, oil, light industry, chemical industry, thermal power plants, sewage treatment and other industries.
Product structure:
Technical parameters:
Measuring range |
0~5m(or customized) |
Accuracy |
0.5 |
Signal output |
4~20mADC, 0~20mA |
Loading resistance |
0~600Ω |
Transmitting distance |
>1000m |
Working voltage |
24VDC |
Working temperature |
-50~ +80 °C |
Environmental temperature |
-40~ +50 °C |
Relative humidity |
≤85% |
Contacting liquid material |
Stainless steel, PP, PTFE |
Installation type |
1,Flange: DN40 (HG/T20592-2009) RF sealing face |
2,G2" thread(customize) |
electrical connection |
M20×1.5 |
Explosion-proof grade |
Exia II CT6Ga Exd II CT6Gb |
How to order: HBY303-1-2-3-4-5-6
1 |
Insert head material |
|
P |
L |
F |
PP |
X |
304 |
316L |
PTFE |
PP |
customize |
2 |
Signal output |
|
4: 4~20mA |
0: 0~20mA |
|
3 |
Indicator |
|
N |
M1 |
M2 |
M3 |
4 |
Flange |
|
40 |
50 |
G |
X |
DN40 |
DN50 |
G2"thread |
Customized |
5 |
Explosion - proof code |
|
No mark: N/A |
i: Exia II CR6Ga |
e:Exd II CT6Gb |
6 |
Measuring range(m) |
|
Measuring length(m) |