• 5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
  • 5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
  • 5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
  • 5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
  • 5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
  • 5% off Vortex Flow Meter for Sealed Pipe Flow Measurement

5% off Vortex Flow Meter for Sealed Pipe Flow Measurement

After-sales Service: Free Technical Guidance
Warranty: 1 Year
Accuracy: ±0.2-0.5%
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
5% off Vortex Flow Meter for Sealed Pipe Flow Measurement pictures & photos
5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
US $100-900 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LUGB
Main Application
Water, Wastewater, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size
DN15-DN300
Sensor
Tube/Flange
Application
Energy Metering
Measuring Media
Liquid
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
JIS
HS Code
9026100000
Production Capacity
400 Pieces Per Week

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 100.00cm
Package Gross Weight
5.000kg

Product Description


Working principle
The LUGB type vortex flowmeter is a flowmeter designed and manufactured using the Karman principle theory of the relationship between the generation of vortices and the flow rate. It can be used to measure the flow of steam, gas and low viscosity liquids. A triangular column (vortex) generating body is inserted into the fluid, and a regular Karman vortex is formed alternately behind the triangular prism, and the separation frequency of the scoring is proportional to the flow velocity(V) of the measured medium. Therefore, the flow rate of the measured fluid can be calculated by detecting the number of vortices by the flow meter sensor head, and the signal processing circuit calculates the volume flow rate of the measured medium according to the sensor aperture.



F=Sr * V/(1-1.27 * d/D)   Q=3600*F/K        M=Q * ρ
5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
Note:
F - Vortex frequency produced by fluid flowing through the triangular prism (Hz)
Q- -volume flow (m3/h)
M - mass flow (kg/h)
Sr - Strohar coefficient (dimensionless)
V - the average velocity of the fluid in the pipe (m/s)
D - Vortex flow sensor inner diameter (m)
Ρ - fluid density (kg/m3)
K - vortex street flow sensor coefficient (number of pulses / m3)

The K value is the number of pulses generated per cubic meter of fluid flowing through the sensor (the number of vortices generated on the back side of the triangular prism). Different vortex flow sensor apertures have different meter values K, and the K value can only be calibrated by the flow calibration device. Acquired.

Product standard: JB/T9249-1999,JJG1029-2007
Flange standard: HG/T20592-2009(Default standard)


Product feature
  1. High accuracy and good repeatability
  2. The detection element is not in contact with the fluid, and the performance is stable and the reliability is high.
  3. Simple and firm structure, movable parts, reliable operation for a long time
  4. Wide measurement range with a range ratio of 1:10 (special up to 15)
  5. The pressure loss is small, about 1/4~1/2 of the orifice flowmeter

Technical parameters
Measuring medium: Liquid, gas, saturated steam, superheated steam
Medium flow rate: Liquid 0.5~7 m/s, gas 4~40 m/s, steam 7~70 m/s
Accuracy level: Liquid 1.0, gas 1.5, insert type 2.5
Possible range of measurement: Reynolds number is 5*103~7*108
Normal measurement range: Reynolds number is 2*104~7*106
Nominal diameter: DN15~DN300 (pipeline type, clamping), DN150~DN2000 (insert type or customized)
Medium temperature: -40~80°C, medium temperature -40~250°C, high temperature -40~350°C
Nominal pressure: 1.0~6.3MPa (>6.3 for customize)
Installation method: Flange type, insert type, clamp type
Output signal: Voltage pulse: low level ≤ 1V, high level ≥ 6V
2-wire system 4-20mA (with RS485, HART)
Pulse frequency 0.1~3000Hz
Power supply: 3-wire pulse output 12V, 24VDC optional
2-wire power supply 24VDC
Local display type 3.6V lithium 7.5AH battery, life > 2 years
Load resistance: 500Ω (when powered by 24VDC)
Electrical interface: M20*1.5, 1/2" NPT
Body material: SS304, SS316L (or for customize)
Head material: Cast aluminum housing, stainless steel housing (or for customize)
Environmental conditions: Temperature -20~+60ºC, relative humidity 5% ~ 90%
Protection level: IP65
Explosion-proof grade: ExdIIBT4Gb, ExiaIIBT4Ga
Flange standard: HG/T20592-2009(Default standard)


Product feature
  1. High accuracy and good repeatability
  2. The detection element is not in contact with the fluid, and the performance is stable and the reliability is high.
  3. Simple and firm structure, movable parts, reliable operation for a long time
  4. Wide measurement range with a range ratio of 1:10 (special up to 15)
  5. The pressure loss is small, about 1/4~1/2 of the orifice flowmeter

Technical parameters
Measuring medium: Liquid, gas, saturated steam, superheated steam
Medium flow rate: Liquid 0.5~7 m/s, gas 4~40 m/s, steam 7~70 m/s
Accuracy level: Liquid 1.0, gas 1.5, insert type 2.5
Possible range of measurement: Reynolds number is 5*103~7*108
Normal measurement range: Reynolds number is 2*104~7*106
Nominal diameter: DN15~DN300 (pipeline type, clamping), DN150~DN2000 (insert type or customized)
Medium temperature: -40~80°C, medium temperature -40~250°C, high temperature -40~350°C
Nominal pressure: 1.0~6.3MPa (>6.3 for customize)
Installation method: Flange type, insert type, clamp type
Output signal: Voltage pulse: low level ≤ 1V, high level ≥ 6V
2-wire system 4-20mA (with RS485, HART)
Pulse frequency 0.1~3000Hz
Power supply: 3-wire pulse output 12V, 24VDC optional
2-wire power supply 24VDC
Local display type 3.6V lithium 7.5AH battery, life > 2 years
Load resistance: 500Ω (when powered by 24VDC)
Electrical interface: M20*1.5, 1/2" NPT
Body material: SS304, SS316L (or for customize)
Head material: Cast aluminum housing, stainless steel housing (or for customize)
Environmental conditions: Temperature -20~+60ºC, relative humidity 5% ~ 90%
Protection level: IP65
Explosion-proof grade: ExdIIBT4Gb, ExiaIIBT4Ga
Product structure

5% off Vortex Flow Meter for Sealed Pipe Flow MeasurementInstruments wiring
5% off Vortex Flow Meter for Sealed Pipe Flow Measurement

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
5% off Vortex Flow Meter for Sealed Pipe Flow Measurement pictures & photos
5% off Vortex Flow Meter for Sealed Pipe Flow Measurement
US $100-900 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
71
Year of Establishment
2005-06-29