• RF Admittance Level Switch Hf Radio Wave Measurement
  • RF Admittance Level Switch Hf Radio Wave Measurement
  • RF Admittance Level Switch Hf Radio Wave Measurement
  • RF Admittance Level Switch Hf Radio Wave Measurement
  • RF Admittance Level Switch Hf Radio Wave Measurement
  • RF Admittance Level Switch Hf Radio Wave Measurement

RF Admittance Level Switch Hf Radio Wave Measurement

Type: RF Admittance
Contact: Contact
Output Signal Type: Switching Type
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
RF Admittance Level Switch Hf Radio Wave Measurement pictures & photos
RF Admittance Level Switch Hf Radio Wave Measurement
US $30-150 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RF
Production Process
Normal Wirewound
Feature
Corrosion Resistant
Material
Stainless Steel
IP Rating
IP65
Certification
CE
Customized
Customized
Transport Package
Carton Packaging
Specification
50.00cm * 50.00cm * 30cm
Trademark
Vacorda
Origin
China
HS Code
9026100000
Production Capacity
400 Pieces Per Week

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 30.00cm
Package Gross Weight
5.000kg

Product Description

Working Principle
The RF admittance level instrument is developed from the capacitive level measurement technology. It is a level control detection instrument with anti-hanging material, more reliable, more accurate and wider applicability. RF admittance is a combination of resistive, capacitive, and inductive components.
RF admittance level control technology is to achieve level measurement by measuring the admittance of the measured medium with high frequency radio waves. The difference between RF admittance technology and capacitive technology lies in the diversity of measurement quantity and three-electrode technology. A shield electrode is added between the measurement electrode and the ground electrode to protect the halo electrode from the influence of the hanging material, and the measurement is more stable. Accurate and reliable.
When the position of the material changes, the three-electrode signal processing circuit compares the comprehensive change signal of impedance, capacitive reactance and inductive reactance with the reference signal. When the difference between the two signals reaches a certain level, the output state of the relay changes, thereby detecting Level changes.

Features
  1. Anti-adhesion: unique circuit design and sensor structure can eliminate the influence of the measurement of the material on the probe, and automatically correct it, avoiding false measurements and signals, and no need to clean the probes regularly;
  2. Maintenance-free: The switch can be moved by mistake, no mechanical wear, no maintenance required;
  3. Strong anti-interference: contact measurement, 0.3 second delay can eliminate the influence of material fluctuation;
  4. Strong adaptability: can detect powder, particles, liquid, viscous, conductive, non-conductive materials.

Application
  1. Power industry: coal transportation, ash removal system (ash bucket, warehouse pump, ash storage)
  2. Building materials industry: such as cement plants
  3. Food industry: flour cans, packaging hoppers
  4. Pharmaceutical industry: various raw materials storage silos, ingredient mixing tanks, etc.
  5. Paper industry: sawdust bin, liquid tank

Technical parameters
Probe material  SS304, SS316L, etc.
Probe pressure  Max 5.0MPa
Sensitivity  0.5PF;
Material temperature  -184 ~ 350 ºC
Switching delay  The delay range is adjustable from 0 to 30 seconds;
Mounting interface  1"NPT, 3/4" NPT or customer flange
Electrical interface  M20*1.5, 1/2 "NPT
Working power  220VAC, 24VDC;
Alarm form  optional upper or lower limit alarm;
Output signal  Relay output
Contact form  SPDT (1 SPDT);
Contact capacity  220VAC 5A;
Power consumption  2.5W max;
Ambient temperature  -40 ~ 80 ºC;
Protection level  IP65;
Explosion-proof grade  ExiaCT5Ga, ExidCT5Gb

Selection table
HKD1000-1 2 3 4 5 6
1 Type
11- Standard type 12-Flat plate type
2 Installation
S1 - 1-1/4"NPT S2 - 3/4"NPT T- Clamp F - Flange
3 Working Power
A - 220VAC B-24VDC
4 Wetted Material
P1 - SS304 P2 - SS316L F - PTFE
5 Working temperature
N-80ºC T - 200ºC S - 400ºC
6 Probe Length (L)
Just right the length (mm)
For example: HKD1000-11S1AP1S100, Standard type, installation for 1-1/4"NPT thread, 220VAC power supply, Wetted material for SS304, Working temperature<400ºC, Probe length=100mm.


Installation
RF Admittance Level Switch Hf Radio Wave Measurement
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
RF Admittance Level Switch Hf Radio Wave Measurement pictures & photos
RF Admittance Level Switch Hf Radio Wave Measurement
US $30-150 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
71
Year of Establishment
2005-06-29