Electromagnetic Flow Meter Lined with PTFE for Highly Corrosive Media
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Free Technical Guidance |
| Warranty: | 1 Year |
Gold Member Since 2019
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Year of Establishment
2005-06-29
Number of Employees
71
Find Similar Products
Basic Info.
- Model NO.
- Electromagnetic flow meter
- Accuracy
- >±1%
- Main Application
- Water, Wastewater, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
- Size
- DN10~DN1200
- Sensor
- Tube/Flange
- Application
- Energy Metering
- Type
- Electromagnetic Flow Meter
- Measuring Media
- Oil
- Measuring Principle
- Electrical Principles
- Measurement Object
- Closed Pipeline
- Certification
- CE, ISO
- Transport Package
- Carton Packaging
- Specification
- 50.00cm * 50.00cm * 70cm
- Trademark
- Vacorda
- Origin
- China
- HS Code
- 9026100000
- Production Capacity
- 400 Pieces Per Week
Product Description
Working Principle
Working principle of electromagnetic flow meter measurement is based on the Faraday law of electromagnetic induction. Measurements of the flow meter tube is lined with insulating material of a non-magnetic alloy spool. Two clicks along the diameter through-wall fixing on the measuring tube. The electrode head is flush with the lining inner surface. Field coil by waves when pulsed excitation by both parties, will be measured perpendicular
to the pipe axis direction produces a magnetic flux density of the magnetic field b. At this point, if you have
some electrical conductivity of fluid flows through the measuring tube, cut magnetic lines of induction electromotive force.
Electromotive force e is proportional to the magnetic flux density B, measure the inside diameter d and the product of the mean velocity v. Electromotive force e (traffic signal) checked out by electrodes and cables to the converter. Converter after the traffic signal will be amplified, to display fluid flow and energy output pulse, analog current signals for flow control and the flow adjustment.
E=KBdv Type: E-- for signal voltage between the electrodes (v)
B-- magnetic flux density (t)
d-- measuring tube diameter (m)
v-- average flow velocity (m/s)
K, d is a constant, due to magnetizing current is constant, b is constant, the E=KBdv, is proportional to the
signal voltage and volumetric flow Q E-. And volume flow rate sensor signal voltage e Q into a linear relationship. Therefore, as long as the measure to determine the flow rate Q, this is the basic operating principle of electromagnetic flowmeter. By E=KBdv today, the measured flow of medium temperature, density, pressure, conductivity, liquid-solid two phase media of liquid and solid ingredients than parameter does not affect the measurement results.
As for the axisymmetric flow flow state as long as it meets (such as laminar or eddying flow) does not affect the measurement results. Thus volume flowmeter Electromagnetic Flowmeter is a real. For manufacturers and users alike, just use plain water after the actual calibration of measuring volume flow of the fluid any other to the point, without the need for human and remediation. This is electromagnetic flowmeter to highlight advantages, is not found in any other flow meters. Measuring tube and block parts of inactivity. So there is little pressure loss and extremely high reliability.
Features:
- No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.
3.On-site modification of the measuring range available.
4.LCD display, easy to use and simple to operate.
5.Using SMD devices and SMT technology.
6.Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.
7.Anti-interference, reliability, measurement range up to 150:1.
8.Ultra low EMI switch, wide range of power supply voltage.
9.RS485, RS232, Hart and Modbus digital communication signal output.
10.Self-checking function.
Application:
Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.
Technical parameters:
| Nominal diameter DN(mm) | 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600,800, 1200 Note: special specifications can be customized |
| Flow direction | positive and negative, net flows |
| Measuring range ratio | 150:1 |
| Repeatability error | ±0.1% |
| Accuracy | Pipe type: 0.5, 1.0 |
| Measured medium temperature | Common rubber lining: -20~+60 ºC High temperature rubber lining: -20~+90 ºC PTFE lining: -30~+100 ºC High temperature vinyl lining: -30~+180 ºC |
| Rated working pressure | Pipe type: DN10~DN65: ≤ 2.5MPa; DN80~DN150: ≤ 1.6MPa; DN200~DN1200: ≤ 1.0MPa Special type up to 10.0MPa |
| Flow measuring range | flow measuring range corresponding to flow rate range is 0.3~15m/s |
| Measured fluid conductivity | ≥5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow) |
| Output | 4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA |
| Load resistance | < 600 Ω |
| Electrode material | 316L, titanium(Ti), tantalum(Ta), Hastelloy(H), Platinum(Pt) or other special electrode materials |
| Protection grade | Standard: IP65; Diving type:IP68 |
| Working power supply | 85~265VAC 45~63HZ |
| Straight pipe length | Pipe type: ≥ 5DN in the upper reaches, downstream :≥2DN |
| Connections | flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements. |
| Explosion-proof mark | ExdCT6 |
| environment temperature | -25 ºC ~+60 ºC |
| Relative humidity | 5%~95% |
| Total power consumption | <20W |
Medium conductivity form
| Medium | Conductivity | Medium | Conductivity |
| All kinds of acid | 10x104~801x104 | beer | 600~800 |
| alkali lye | 8x104~30x104 | malt wort | 500~1000 |
| distilled water | 0.01~5 | milk | 200~300 |
| Water/drink | 200~800 | Fruit sauce | 400~1000 |
Selection of Integrated and Separated type
Integrated type: if the environment is nice, normally choose integrated flow meter, which consists of sensor
and Converter.
Separated type: sensor is apart from converter. The conditions is as follows:
- It is more than 60ºC for environment temperature or surface temperature of flow meter.
- occasion of Pipeline vibration strongly.
- Occasion that it is corrosive medium for Aluminum transmitter.
- High temperature or corrosive gas
- Flow meter installed at high place and no easy for debugging.
- Customer should note the distance of sensor and converter, generally no more than 100m and converter is hanging on the wall.
Electrode, Ground ring material:
| Electrode material | Performance of corrosive medium |
| SS316L | Nitric acid,<5% sulphuric acid in warm room, boiled phosphoric acid,acetic acid,aqueous slkali,sulfurous acid, seawater,acetic acid |
| Hastelloy | Oxidizing acid,sulphuric acid,seawater,aqueous slkali |
| Titanium | Seawater,chloride,hypochlorite,Acid chloride(fuming nitric acid),organic acid,alkali |
| Tantalum | Except ,fuming sulfuric acid,alkali etc chemical medium |
| Platinum | All kinds of acid,alkali, no including chloroazotic acid |
Lining material:
| Lining material | Name | Symbol | Function | Max temp. | Applicable liquids |
| Rubber | Chloroprene rubber | / | Abrasion resistance,weak acid,alkali | / | Tap water, Industrial water,seawater |
| Urethane rubber | / | Nice abrasion resistance,weak acid,alkali | <80ºC | / | |
| Fluoro plastic | PTFE | F4/PTFE | Fuming muriatic acid, sulphuric acid,strong alkali | <180ºC | High Corrosive acid-base salt liquid |
| Tetrafluoroethylene | F46/FEP | Function weaker than f4 | / | Corrosive acid-base salt liquid | |
| Plastics | Tetrafluoroethylene | F4/ETFE | Function weaker than f4 | / | Corrosive acid-base salt liquid |
| Polyethylene | PO | Stable | <60ºC | sewage | |
| Polyphenyl thioether | PPS | / | <150ºC |
Flow measuring scope
Max flow and min flow must suit the data in the table.
| Diameter (mm) | 10 | 15 | 20 | 25 | 32 | 40 | 50 | 65 |
| Max flow | 2.8 | 6.4 | 13.3 | 17.7 | 28.9 | 45.0 | 71.0 | 119 |
| Min flow | 0.08 | 0.19 | 0.34 | 0.53 | 0.729 | 1.35 | 2.13 | 3.57 |
| Diameter (mm) | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 |
| Max flow | 181 | 283 | 442 | 636 | 1130 | 1770 | 2540 | 3460 |
| Min flow | 5.43 | 8.49 | 13.3 | 19.1 | 33.9 | 53.1 | 76.2 | 104 |
| Diameter (mm) | 400 | 450 | 500 | 600 | 700 | 800 | 900 | 1000 |
| Max flow | 4520 | 5720 | 7070 | 10200 | 13850 | 18100 | 22900 | 28300 |
| Min flow | 136 | 172 | 212 | 306 | 416 | 543 | 687 | 849 |
| Diameter (mm) | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 | |
| Max flow | 40700 | 55400 | 72400 | 91600 | 113100 | 136800 | 162800 | |
| Min flow | 1221 | 1662 | 2172 | 2748 | 3393 | 4100 | 4480 |
Installation site suggestion
- To avoid magnetic field environment, and magnetic device, in case that it affects magnetic and signal output.
- Dry and ventilated place for installation.
- Avoid the sun and rain, and high temperature above 60ºC and humidity above 95%
- Place that easy for installation and moving
- Flow meter should be installed behind pump, and valve must be connected with outflow part of flowmeter.
Installation requirement:
- Transmitter can be installed on the straight pipe and horizontal pipe
- Full pipe flow to avoid the electrode touching with air.
- Vertical installation to abrade lining equally to prolong the lifetime, if the medium is mixture of liquid and water.
- Change installation methods: choose smaller diameter if the flow rate doesn't reach the requirement.
- Change Some part pipe to make diameter same as transmitter's, but straight pipe must be: inflow part>= 5DN, outflow part>=2DN(DN pipe diameter)

Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Flow Instruments
- Electromagnetic flowmeter
- Electromagnetic Flow Meter Lined with PTFE for Highly Corrosive Media
Related Categories
Hot Searches
More