Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HKLD intelligent electromagnetic flowmeter is a kind of fully intelligent electromagnetic flowmeter developed by our company with advanced technology at home and abroad. Its Chinese electromagnetic converter core uses high-speed central processing unit. The calculation speed is very fast, the accuracy is high, and the measurement performance is reliable. The circuit design of the converter adopts international advanced technology, the input impedance is up to 10 ohms, the CMRR is better than 100db, and the rejection ability for external interference and 60Hz/50Hz interference is better than 90db. It can measure the flow rate of fluid medium with lower conductivity.
Nominal diameter DN(mm) | 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600,800, 1200 Note: special specifications can be customized |
Flow direction | positive and negative, net flows |
Measuring range ratio | 150:1 |
Repeatability error | ±0.1% |
Accuracy | Pipe type: 0.5, 1.0 |
Measured medium temperature | Common rubber lining: -20~+60 ºC High temperature rubber lining: -20~+90 ºC PTFE lining: -30~+100 ºC High temperature vinyl lining: -30~+180 ºC |
Rated working pressure | Pipe type: DN10~DN65: ≤ 2.5MPa; DN80~DN150: ≤ 1.6MPa; DN200~DN1200: ≤ 1.0MPa Special type up to 10.0MPa |
Flow measuring range | flow measuring range corresponding to flow rate range is 0.3~15m/s |
Measured fluid conductivity | ≥5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow) |
Output | 4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA |
Load resistance | < 600 Ω |
Electrode material | 316L, titanium(Ti), tantalum(Ta), Hastelloy(H), Platinum(Pt) or other special electrode materials |
Protection grade | Standard: IP65; Diving type:IP68 |
Working power supply | 85~265VAC 45~63HZ |
Straight pipe length | Pipe type: ≥ 5DN in the upper reaches, downstream :≥2DN |
Connections | flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements. |
Explosion-proof mark | ExdIICT6 |
environment temperature | -25 ºC ~+60 ºC |
Relative humidity | 5%~95% |
Total power consumption | <20W |