• Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments
  • Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments
  • Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments
  • Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments
  • Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments
  • Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments

Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments

After-sales Service: Free Technical Guidance
Principle: Magnetic Sensors
Range: 0-60m
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments pictures & photos
Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments
US $90-700 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
UHC
Measurement Accuracy
±3mm
Accuracy
0.1%
Kind
Magnetic Flap
Structure
All in One
Warranty
1 Year
Certification
CE
Material
SS304
Process Temperature
-190~425℃
Transport Package
Carton Packaging
Specification
50.00cm * 50.00cm * 100cm
Trademark
Vacorda
Origin
China
HS Code
9026100000
Production Capacity
500 Pieces Per Week

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 100.00cm
Package Gross Weight
10.000kg

Product Description

Magnetic Column Liquid Level Gauge
Working Principle:
The UHC series magnetic column level gauge is connected to the vessel through a gas phase and liquid phase connection flange using the principle of a linker. According to the principle of buoyancy and magnetic coupling, the magnetic float in the measuring cylinder (connector) drives the two-color flip on the external display of the measuring cylinder to rise (lower) with the measured liquid level. When the liquid level rises, the magnetic float magnetic float drives the flip column to flip 180°, showing red and green; when the liquid level drops, the magnetic float drives the flip column to rotate 180° in the reverse direction, showing white. The height of the red band (or green band) is the height of the measured liquid level, which achieves the purpose of measuring and displaying the position of the measured liquid (boundary) surface.
Each magnetic flip column has a two-color axially symmetric structure with a spacing of 10 mm between the two magnetic flip columns, with white and red (green) indicating the meteorological and liquid phase portions respectively, and the red (or green) and white junctions are The boundary between the gas phase and the liquid phase. The level gauge measures both the liquid level and the interface of two different density media.
Product Standards:HG/T 2742-1995,HG/T21584-95, Flange standard:HG/T20592~20615-2009

Features:                   
 Simple structure, good stability, reliability and durability.

 Isolated medium, indicator, transmitter and switch
 Wide range of operating pressure: vacuum to 42Mpa
 Wide range of operating temperature: -190ºC to 425 ºC
 Independent of medium's physical and chemical states. 
 SPST or SPDT available
 Optioning float level transducer, capacitive two-wire level transducer and Magnetostrictive level sensor to transmit 4-20mA DC signal (or HART) and realize remote control and measurement.
 Two-wire level transducer can be with LED digital indicator for night observation.

Application:  
UHC series magnetic column liquid level gauge is widely used in petroleum, chemical industry, oil field, pharmaceuticals industry, food, wine industry etc., suitable for level measurements under the environment of high/low temperature., high pressure, strong corrosion, toxicity.

Optional items:
SPST or SPDT no standby power alarm switch could realize high-low level measurement and alarm. Alarm switch number is unlimited.
Optional two-wire magnetic liquid level sensor, output 4~20mADC signal for remote measurement and control.
Optional two-wire magnetostrictive and capacitive liquid level sensor, output 4~20mADC signal for high precision, continuous measurement and control.
Top and bottom structure connection can be selected.
4~20mADC + HART protocol.



Main technical parameters:
Basic part
C-C Distance: 150~6000mm(Customize for more)
Medium density: >0.45g/cm3
Nominal pressure: PN2.5~PN420 (x 0.1MPa)
Material: 304,316L, or customize
Operating temperature: -190 ~ +425 °C
Top structure: Code 1 for standard (Page 4)
Bottom structure: Code 9 for standard (Page 4)
Protection grade: IP65
 
Magnetic alarm switch(Optional items)
  1. SPDT(250VAC 1A 60W)
  2. SPST(250VAC 0.5A 20W)
  3. Protection grade: IP65
  4. Explosion-proof: Exd
  5. More infomation see page 8
Level transmitter(Optional items)
  1. Output signal: 4~20mADC
  2. Power supply:16~30VDC
  3. Protection class: IP65
  4. Explosion-proof: ExiaII CT6Ga ExdII CT6Gb
  5. More infomation see page 5
Optional item of liquid level transmitter

Working principle:

Magnetic liquid level transmitter
It consists of imported reed switch, precision resistor and conversion circuit. When the magnetic flux of the magnetic float in the magnetic flip column level gauge is closed to the reed switch at a certain position, the resistance of the three-wire potentiometer is proportional to the liquid level change, and the change of the liquid level is converted into the 4~20mADC signal by the conversion circuit. Output for detection and transmission of liquid level signals.

Magnetostrictive level sensor
It is a new generation of liquid level sensor with high measurement accuracy. It is stable in performance and is not affected by gas, temperature and pressure changes in the tank. Two-wire 4~20mA (with HART), Modbus and other signal outputs are available.







How to order:            /
1 Resolution code
  B10: 10mm (common) B5: 5mm
  C1: Capacitive sensor C2: Magnetostrictive sensor
2 Code of Explosion-proof
  No mark: N/A i: Intrinsically Safe ExiaCT6Ga
  e: ExdCT6Gb  
3 Code of displayer
  No mark: N/A M3: LED +HART
  M2: LED displayer M4:0.56"LED displayer
4 Code of measuring (mm)
  Directly write measurement range values
5 Code of ambient temperature
  Directly write measurement range values

Note: 1. Match the magnetic column liquid level gauge could ignore "4" and"5"
     2. Purchase level transmitter alone, should mark "4" and"5"
     3. We offer customize

Electrical connections:
Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature EnvironmentsNote: as the same resolution, the measuring range wider, the accuracy will be higher.
For example: resolution:10mm, measuring range:1000mm, accuracy:1%
            resolution:10mm, measuring range:2000mm, accuracy:2%

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments pictures & photos
Magnetic Column Liquid Level Gauge for Frost Protection in Low Temperature Environments
US $90-700 / Piece
Min. Order: 1 Piece
Gold Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
71
Year of Establishment
2005-06-29